Flammability
Flammability according to UL
Data of the incendiary class according
to the UL 94 specification.
UL Underwriters Laboratories, Inc., USA
This test for technical plastic is widespread. The 4 incendiary classes are classified according to their burning behavior:
UL 94
HB Testing of the incendiary behavior of a
horizontally held test piece.
UL 94 V-2
UL 94 V-1 Testing of the incendiary behavior of
a vertically suspended test piece.
UL 94 V-0
Incendiary class V
The following criteria must be fulfilled
for the respective classification:
|
Classification
criteria
|
V-0
|
V-1
|
V-2
|
|
Maximum burning duration
|
£ 10 s
|
£ 30 s
|
£ 30 s
|
|
Total burning duration of 5 samples
after 10 x flamings
|
£ 50 s
|
£ 250 s
|
£ 250 s
|
|
Ignition of cotton wool laid underneath
by burning drips
|
no
|
no
|
yes
|
|
Maximum duration of incandescence after
the 2nd flaming
|
30 s
|
60 s
|
50 s
|
Incendiary class HB
The requirements in this case are:
- Incendiary speed <38.1 mm per min at
sample thicknesses of 3.05 to 12.7 mm
or
- Incendiary speed <76.2 mm per min at sample thicknesses under 3.5 mm
or
- maximum sp
read of flames < 102 mm
|